Powador 500 Kilowatt-Station
Powador 500 Kilowatt-Station with a rated AC power of 500 kVA. Suitable as a single station for PV installations with a generator power of up to 600 kW.
Electrical Data
| Input Variables | |
|---|---|
| Max. recommended PV generator power | 600 kW |
| MPP range | 450 V … 830 V |
| No-load voltage | 1,000 V* |
| Max. input current | 2 x 611 A |
| Ripple voltage | < 3% |
| Ripple current | < 4% |
| Output Variables | |
| Rated output | 500 kVA |
| Line voltage | acc. to local requirements |
| Rated current | 14.4 A |
| Rated frequency | 50 Hz / 60 Hz |
| cos phi | 0.80 inductive ... 0.80 capacitive |
| Distortion factor for rated output | < 3 % at rated output power |
| General Electrical Data | |
| Max. efficiency | 98.1% ** |
| European efficiency | 97.8% ** |
| Internal consumption | < 1% of the rated power |
| Standby consumption | < 200 W |
| Grid monitoring | acc. to local requirements |
| Auxiliary supply | 230 V |
Mechanical Data
| Display | TFT LCD Touchscreen |
| Interfaces | RS485 / Ethernet / USB, 4 x analog inputs, 1 x digital input / 1 x S0 input, 1 x digital output / 1 x S0 output, SD card |
| Ambient temperature | -20 °C … +50 °C, non-condensing |
| Cooling | fan (max. 8.080 m³/h) |
| EMC | acc. EN 61000-6-2 / EN 61000-6-4 |
| CE conformity | yes |
| H x W x D | 3,560 x 4,780 x 2,980 mm |
| Weight | ca. 31 t |
* To protect the hardware, the inverter starts up only at voltages < 950 V
** Inverter efficiency. Transformer efficiency may vary
** Inverter efficiency. Transformer efficiency may vary
Subject to change without prior notice (10/2012)
Data Sheet
| Data sheet Powador 500 kW stationFormat:
PDF Size: 261.65 KB Version: 120604 | ![]() ![]() |
Technical Information
| Powador XP200-HV TL Transformer Specification Format:
PDF Size: 75.83 KB Version: 120724 | ![]() ![]() |